Standard Motor Capabilities

Standard Motor Capabilities

Standard Motor Capabilities established by the National Electrical Manufacturers Association (NEMA)and expressed in the MG- I standard (part 30), indicate that standard NEMA type B motors can withstand 1000 volts peak at a minimum rise time of 2 u-sec (microseconds). Therefore to protect standard NEMA Design B motors, one should limit peak voltage to 1KV and reduce the voltage rise to less than 500 volts per micro-second.